Hieff Canace™ Uracil+ High-Fidelity DNA polymerase (3 U/μL)

Details:

Product Description

Hieff Canace™ Uracil+ High-Fidelity DNA polymerase, is a new generation of high-fidelity DNA Polymerase based on Pfu DNA Polymerase. The Hieff Canace™ Uracil+ high-fidelity DNA Polymerase enables rapid and accurate PCR reactions for complex templates. Its fidelity is improved significantly, and it completely avoids the amplification failure caused by using dUTP-containing primers/templates/dNTPs. The product is equipped with an optimized enzyme buffer and the addition of PCR-enhancing components, making the enzyme highly efficient and adaptable to a wide range of templates, and suitable for amplification of complex templates.

Product Components

Component number

Components

Cat#/Size

14384ES03

14384ES08

14384ES50

14384-A

Hieff CanaceTM Uracil+ High-Fidelity DNA Polymerase (3 U/μL)

1 mL

5 mL

50 mL

Shipping and Storage

The components are shipped with ice packs and can be stored at -20°C for 1 year.

Product Application

High-fidelity library amplification using dUTP-containing primers/templates/dNTPs.

Cautions

1. For your safety and health, please wear lab coats and disposable gloves for operation.

2. For research use only!

Instructions

Hieff Canace™ Uracil+ High-Fidelity DNA polymerase is used in a slightly different way than conventional high-fidelity enzymes. Please read the instructions carefully before use.

1. Recommended reaction system

All operations should be carried out on the ice. 2×CanaceTM Uracil+ PCR buffer should be well mixed after thawing. Before the system configuration, please preheat the PCR instrument. After the addition of the components, mix the sample well by a pipette and spin it down to the bottom of the tube, then place it in the preheated PCR instrument for amplification. After use, return all components to -20 °C for storage.

Table 1. PCR amplification reaction

Components

Volume

Template or ligation product

X µL

2×CanaceTM Uracil+ PCR buffer (containing Mg2+, dNTPs) (Cat#15423)

25 µL

Forward primer (10-25 μM)

1-2.5 µL

Reverse primer (10-25 μM)

1-2.5 µL

Hieff CanaceTM Uracil+ High-Fidelity DNA polymerase (3 U/µL)

1 U

ddH2O

Total to 50 µL

[Notes]:

1)Reagents: Sufficiently thaw each component before use;

2)Templates: The use of purified high-quality DNA templates can significantly improve the efficiency and success rate of amplification;

3)dNTPs: The recommended final dNTPs concentration is 200 μM. The dNTPs provided in the kit do not contain dUTP. If special circumstances require the preparation of dUTP-containing templates, additional dUTP can be added to a final concentration of 400 μM.

4)Polymerase concentration: 1 U/50 μL is recommended. It can be optimized between 0.5-2 U/50 μL, does not exceed 2 U/50 μL. In order to prevent the polymerase from degrading primers due to 3 '→5' exonuclide activity, it is suggested to add polymerase to the reaction system in the last step.

5)Mg2+ final concentration: The final concentration of the system is 2 mM. Please ask our company to provide a buffer with low Mg2+ concentration or without Mg2+ if you have special needs.

2. Recommended reaction procedure

Table 2. PCR amplification reaction procedure

Step

Temperature

Duration

Number of cycles

Initial Denaturation

98°C

1 min

1

Denaturation

98°C

10 sec

1~15

Annealing

60°C

30 sec

Extension

72°C

30 sec

Final Extension

72°C

5 min

1

Hold

4°C

-

-

[Notes]:

1) Initial denaturation temperature and time: 98℃ is recommended. The recommended time is 30 sec for simple templates such as plasmid DNA, 1 min for libraries, 3 min for complex templates such as cDNA and genomic DNA, and 5-10 min for high GC content templates.

2) Annealing temperature and time: 60℃ is recommended, or a temperature gradient can be set up to find the optimal temperature for primer annealing according to needs. The recommended annealing time is 20 sec and can be adjusted within 10-30 sec. Too long an annealing time may lead to dispersion of the amplified products on the gel.

3)Extension temperature and time: 72℃ is recommended. The extension time is adjusted according to actual needs.

COA Please fill out the COA application form

Catalog No.:*

Name*

phone Number:*

Lot:*

Email*

Country:*

Company/Institute:*