UCF.ME® High Affinity RNase Inhibitor (40 U/μL)

Details:

Product description

UCF.METM High Affinity RNase Inhibitor (40 U/μL) is a recombinant porcine RNase inhibitor expressed in E. coli. It specifically inhibits the activity of RNases A, B and C through binding noncovalently. This product can be compatible with HifairTM Ultra Reverse Transcriptase (200 U/μL) (Cat#14604ES) and various DNA polymerases verified by RT-PCR and RT-qPCR. UCF.METM High Affinity RNase Inhibitor (40 U/μL) is lower with the purification process specially developed by YEASEN, which is suitable for application with more stringent requirements on background bacteria, such as pathogen microorganism detection.

Specifications

Cat.No.

14675ES05 / 14675ES20 / 14675ES60

Size

2 KU / 20 KU / 100 KU

Unit Definition

The required amount of RNase Inhibitor to inhibit 50% activity of 5-ng RNase A is defined as one unit. The activity of RNase A is measured by hydrolyzing of cyclic 2', 3'-CMP to generate 3'-CMP.

Components

Name

14675ES05

14675ES20

14675ES60

UCF.METM High Affinity RNase Inhibitor (40 U/μL)

50 μL

500 μL

2.5 mL

Storage

This product should be stored at -25~-15℃ for 2 years.

Instructions

1. Add the following components to a nuclease-free microcentrifuge tube:

Components

Volume (μL)

RNase-free ddH2O

to 20

5×HifairTM Ultra Reverse Transcriptase Reaction Buffer*

4

Oligo (dT)18 (50 μM)

1

dNTP Mix (10 mM each)

1

UCF.METM High Affinity RNase Inhibitor (40 U/μL)

0.5-1

HifairTM Ultra Reverse Transcriptase (200 U/μL)*

1

RNA template

Total RNA:1 ng-5 μg

*According to the specific experimental application, 14604ES can be purchased for use together.

2.Thermal cycling protocol

Temperature

Time

50℃*

15 min

85℃**

5 min

*Reverse transcription temperature: When used with 14604ES, 50℃ is recommended; For high GC content templates or complex templates, the reverse transcription temperature can be increased to 55℃-60℃.

**inactivate the reaction by heating at 85℃ for 5 min.

3. The products of reverse transcriptase reaction can be immediately used for subsequent PCR or qPCR reactions, and can be stored at -25~-15℃ for short-term storage. If long-term storage is required, it is recommended to store them at -80℃ after packaging to avoid repeated freeze-thaw products.

 Notes

1. This product is for scientific research purposes only.

2. Please wear the necessary PPE, such lab coat and gloves, to ensure your health and safety.